Net Zero Energy Building Design Approaches for Building All over the World

Case of Net Zero Energy Building all over the world
Many are skeptical about the reality of Net Zero Energy Building Design. As such I though it is best to show you the buildings which have achieved the Net Zero Energy Building Design status. This Net Zero Energy Building Design approaches and strategies has become a trend world wide as the movement is catching on quire rapidly. Here there are 5 cases of the strategies adopted world over from Indonesia, Malaysia to the US.
Case 1

Apartment in NY ( read on Apartment in NY )
The Apartment had 48 apartments of an gross area of 53,000-sq-ft
Approaches to Net Zero Energy Designs strategies(The strategies adopted contrived a 90% reduction of consumption of energy);
• wall and roof insulation,
• window glass with low-e coatings and insulated frames,
• shading of building
• Reduction of infiltration through building skin
• Compartmentalization of ventilation spaces provided the best controlled fresh air into the apartment spaces.
• A high-performance air-source heat pump was introduced as a heating plus cooling system.
• One VRF outdoor condensing unit is recommended per apartment
• Domestic hot water included heat recovery from the drain as a pre-heater and recovering the waste heat from the VRF system by using a heat exchanger.
• Improved zone temperature control and substantially reduced energy usage
• Higher-efficiency cooling/heating
• Improved tenant comfort; potential to sub meter heating, cooling, and DHW
• Resiliency (no boiler on the lower floors); and most important, dramatically lower carbon emissions.
• Lighting strategies include low lighting power density (LPD) design solutions while maintaining acceptable levels of illumination. Where applicable, occupancy sensors and bi-level lighting controls are evaluated. The most efficient available appliances are considered for apartments and common areas.
• Solar photovoltaic (PV) arrays
• High performing Appliances s such as : refrigerators, Clothes dryer, Television and TV set-top (cable) boxes

 

Case 2

The Bullitt Center in Seattle, Washington, 6 storey Office block of approx 60,000ft2

Approaches to Net Zero Energy Building Design strategies:
• Day lighting harvesting
• geothermal heating and cooling,
• Operable windows and other measures to increase its energy efficiency.
• increase the height of each floor of the building to allow for improved day lighting further into the core of the structure,
• Reducing the need for heat-generating light fixtures.
• Geothermal and radiant floor heating & cooling are used to efficiently moderate temperatures
• The BMS controls the heating & cooling , the window shades, operable windows , composting, water treatment, and ventilation.
• photo voltaic used to create renewable energy
Case 3
Pusat Tenaga Malaysia Zero Energy Office Building ( PTM ZEO)

The area of building was 43,000sq ft averaging BEI of 35kW/sqm.year with a reduction of 80% of the national average BEI
It is the world’s first net zero energy commercial office building.

Approaches to Net Zero Energy Designs strategies :
• Double-pane windows reducing heat gain and provide day light harvesting.
• Energy efficient building envelope.
• Day lighting with controls of blinds and light shelves.
• High efficiency pumps and fans.
• Desiccant heat wheel DE-humidification.
• Energy efficient office equipment.
• Concrete slab thermal cooling and storage.
• Wet/ trickling water night cooling roof.
• Phase change thermal storage.
• photo voltaic used to create renewable energy
Case 4

NREL Building, USA

The floor area is about Area-360,000sq ft , energy use intensity target of the new building is 35 kBtu/SF/year, (110kWh/m2/year)
Approaches to Net Zero Energy Building Designs strategies :
The largest commercial Net-Zero Energy Building in the United States
Energy performance for the facility is 50% better than ASHRAE 90.1 standards.
• orientation of the building to minimize heat gain and
• maximize day lighting harvesting
• operable triple-glazed windows,
• hydronic heating and cooling using thermal slabs, and
• demand-controlled outside air system with energy recovery.
• a combination of evaporative cooling,
• outside air ventilation,
• waste heat capture
• efficient servers
• The data center has a remarkable power usage effectiveness (PUE) rating of 1.12 compared to a national average of 1.91
• photo voltaic used to create renewable energy 2.5 MW solar PV rooftop and parking canopy
Case 5

Pertamina Building
There Pertamina Building , a 99 storey office tower will be a Net Zero Energy Building

Approaches to Net Zero Energy Building Designs strategies :
• A ‘wind funnel generate energy.
• The tower’s curved facade will reduce the heat gain throughout the year.
• Exterior sun shades will dramatically improve the workplace environment
• Artificial lighting in the office
• photo voltaic used to create renewable energy
Other case are reported here read on: http://living-future.org/casestudies
Prepared by Net Zero Energy Building Architect Perumal Nagapushnam